#8 closed defect (fixed)
scanlen in PHU bears no relation to actual length of file
Reported by: | Matthew Whiting | Owned by: | Matthew Whiting |
---|---|---|---|
Priority: | major | Component: | pvoconvert: FITS access |
Version: | Keywords: | ||
Cc: |
Description
Some of the files in the $S70TAPES directory are not 70cm survey files but timing observations, and are longer than the standard length. However, the SCANLEN header in the PHU is set as a constant, rather than reading in the SCAN_LEN parameter in the tape file. Need to change this.
Note: See
TracTickets for help on using
tickets.
Fixed in [84] by reading the SCAN_LEN parameter instead.