Opened 15 years ago

Closed 15 years ago

#73 closed defect (fixed)

invert fails with unrecognised beam

Reported by: JamieStevens Owned by: MarkWieringa
Priority: major Milestone:
Component: MIRIAD - CABB branch Version:
Keywords: invert Cc:
Estimated Number of Hours: 0 Add Hours to Ticket: 1
Billable?: yes Total Hours: 0

Description

When attempting to produce an image cube, I get the following output:

invert vis=0208-512.5500 map=0208-512.5500.map beam=0208-512.5500.beam options=double slop=0.5

invert: Version 1.3, 2007/04/03 00:01:00 UTC

Reading the visibility data ... ### Warning: Noise variance cannot be determined for 0208-512.5500 ### Warning: ... variable systemp is missing or non-positive ### Warning: Set the variable(s) using puthd Making cubes with 2049 planes Visibilities accepted: 920 ### Warning: Number of channels with no good data: 773 ### Fatal Error: Unrecognised primary beam type ATCABB

Change History (1)

comment:1 Changed 15 years ago by MarkWieringa

Add Hours to Ticket: 01
Resolution: fixed
Status: newclosed

Changed atlod to set telescope keyword to ATCA and instrument keyword to CABB. Previously telescope was set to atcabb and invert complained it didn't know the primary beam for this telescope. Still to solve: noise variance/systemp issues ( see #44 and #45)