Opened 17 years ago

Closed 15 years ago

#17 closed task (fixed)

ATLOD can read in a simulated datafile containing one correlator mode

Reported by: VincentMcIntyre Owned by: MarkWieringa
Priority: major Milestone: 7. Stage 1 - available for testing
Component: MIRIAD - CABB branch Version:
Keywords: Cc:
Estimated Number of Hours: Add Hours to Ticket: 0
Billable?: no Total Hours: 4.0

Description (last modified by VincentMcIntyre)

Warwick will be writing out RPFITS data files in the Marsfield labs some time in October. By the end of that month we should be able to read such files in correctly.

We will have to adjust the default MAXCHAN to make the modes with the highest number of channels.

Question: does the observing(correlator control) system always close the currently open file, if there is a change of correlator mode?

Change History (6)

comment:1 Changed 17 years ago by VincentMcIntyre

Summary: ATLOD can read in a simulated datafileATLOD can read in a simulated datafile containing one correlator mode

comment:2 Changed 17 years ago by VincentMcIntyre

Description: modified (diff)

comment:3 Changed 17 years ago by VincentMcIntyre

Billable?: unset
Component: progMIRIAD - CABB branch

comment:4 Changed 16 years ago by MarkWieringa

Add Hours to Ticket: 4
Status: newassigned
Total Hours: 04.0

comment:5 Changed 16 years ago by MarkWieringa

This is essentially done for simulated data. Once real cabb data arrives this will need tweaking.

comment:6 Changed 15 years ago by MarkWieringa

Resolution: fixed
Status: assignedclosed

atlod can read current CABB data. Note that current data is just continuum with 2049 channels, no zoom bands expected until mid 2009.

Note: See TracTickets for help on using tickets.