#108 closed defect (fixed)

uvspec frequency axis is inaccurate

Reported by: MarkWieringa Owned by: MarkWieringa
Priority: major Milestone:
Component: MIRIAD - CABB branch Version:
Keywords: Cc:
Estimated Number of Hours: 0 Add Hours to Ticket: 0
Billable?: yes Total Hours: 6

Description

It looks like the uvspec frequency labelling runs into problems at CABB zoom band resolution. 0.5kHz channel with GHz center freq means 10-7 resolution needed on freq axis, beyond single precision real.

Change History (1)

comment:1 Changed 14 years ago by MarkWieringa

Resolution: fixed
Status: newclosed
Total Hours: 06

I've checked in a fix. When the frequency resolution gets too high or the axis range too small, it subtracts an appropriate offset before plotting. In the cases I've tried the axis=freq,amp and axis=chan,amp plots now look the same, but some tweaking may be needed to the tolerances for offset/no offset plotting to cover all cases.