Flux unit conversion not working with existing reconstruction
Reported by: | MatthewWhiting | Owned by: | MatthewWhiting |
---|---|---|---|
Priority: | normal | Milestone: | Release-1.2 |
Component: | Input | Version: | 1.1.13 |
Severity: | normal | Keywords: | |
Cc: |
Description
When an existing reconstruction cube is read in, it appears that the flux unit conversion (eg. from Jy/beam to mJy/beam) does not occur. This means specifying a threshold=10 doesn't find anything (which it does when doing the reconstruction from scratch), but a threshold=0.01 does.
Clearly a bit of code missing in the reading of existing cubes.
Change History (3)
comment:1 Changed 12 years ago by
Milestone: | Release-1.2 → Release-1.1.14 |
---|
comment:2 Changed 12 years ago by
Status: | new → assigned |
---|
comment:3 Changed 12 years ago by
Resolution: | → fixed |
---|---|
Status: | assigned → closed |
Smoothing works fine now as well. Think we can close this.
Note: See
TracTickets for help on using
tickets.
Largely fixed in [899] and [901]. Have tested with the reconstruction, but not yet with the smoothing.