Opened 15 years ago

Closed 15 years ago

#100 closed defect (fixed)

Can uvsplit separate two IFs at the same frequency

Reported by: MarkWieringa Owned by: MarkWieringa
Priority: major Milestone:
Component: MIRIAD - CABB branch Version:
Keywords: uvsplit CABB Cc:
Estimated Number of Hours: 1.5 Add Hours to Ticket: 0
Billable?: yes Total Hours: 0

Description

Currently 20 and 13cm data with CABB tends to have two IFs at the same center freq. It would be good if uvsplit could either separate these or warn about it, because it causes trouble downstream (mfcal, gpcal).

Change History (1)

comment:1 Changed 15 years ago by MarkWieringa

Estimated Number of Hours: 01.5
Resolution: fixed
Status: newclosed

Yes. When split by frequency is requested (the default) identical frequencies on different IFs will now be separated in to files named like: 1934-638.1750.1 1934-638.1750.2 etc.