Opened 13 years ago

Closed 12 years ago

#127 closed defect (fixed)

Flux unit conversion not working with existing reconstruction

Reported by: MatthewWhiting Owned by: MatthewWhiting
Priority: normal Milestone: Release-1.2
Component: Input Version: 1.1.13
Severity: normal Keywords:
Cc:

Description

When an existing reconstruction cube is read in, it appears that the flux unit conversion (eg. from Jy/beam to mJy/beam) does not occur. This means specifying a threshold=10 doesn't find anything (which it does when doing the reconstruction from scratch), but a threshold=0.01 does.

Clearly a bit of code missing in the reading of existing cubes.

Change History (3)

comment:1 Changed 12 years ago by MatthewWhiting

Milestone: Release-1.2Release-1.1.14

comment:2 Changed 12 years ago by MatthewWhiting

Status: newassigned

Largely fixed in [899] and [901]. Have tested with the reconstruction, but not yet with the smoothing.

comment:3 Changed 12 years ago by MatthewWhiting

Resolution: fixed
Status: assignedclosed

Smoothing works fine now as well. Think we can close this.

Note: See TracTickets for help on using tickets.