source: trunk/docs/app-param.tex @ 675

Last change on this file since 675 was 675, checked in by MatthewWhiting, 14 years ago

Changes to make the use of the new beam parameters more transparent. All seems to work fine.

File size: 18.6 KB
Line 
1% -----------------------------------------------------------------------
2% app-param.tex: Section listing all the possible input parameters and
3%                their defaults.
4% -----------------------------------------------------------------------
5% Copyright (C) 2006, Matthew Whiting, ATNF
6%
7% This program is free software; you can redistribute it and/or modify it
8% under the terms of the GNU General Public License as published by the
9% Free Software Foundation; either version 2 of the License, or (at your
10% option) any later version.
11%
12% Duchamp is distributed in the hope that it will be useful, but WITHOUT
13% ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or
14% FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General Public License
15% for more details.
16%
17% You should have received a copy of the GNU General Public License
18% along with Duchamp; if not, write to the Free Software Foundation,
19% Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307, USA
20%
21% Correspondence concerning Duchamp may be directed to:
22%    Internet email: Matthew.Whiting [at] atnf.csiro.au
23%    Postal address: Dr. Matthew Whiting
24%                    Australia Telescope National Facility, CSIRO
25%                    PO Box 76
26%                    Epping NSW 1710
27%                    AUSTRALIA
28% -----------------------------------------------------------------------
29\secA{Available parameters}
30\label{app-param}
31
32The full list of parameters that can be listed in the input file are
33given here. If not listed, they take the default value given in
34parentheses. Since the order of the parameters in the input file does
35not matter, they are grouped here in logical sections.
36
37\secB*{Input related}
38\begin{Lentry}
39\item[{ImageFile [no default]}] The filename of the
40  data cube to be analysed.
41\item[{flagSubsection [false]}] A flag to indicate whether one
42  wants a subsection of the requested image.
43\item[{Subsection [ [*,*,*] ]}] The requested subsection
44 -- see \S\ref{sec-input} for details on the subsection format.  If
45 the full range of a dimension is required, use a \texttt{*} (thus the
46 default is the full cube).
47\item[{flagReconExists [false]}] A flag to indicate whether the
48  reconstructed array has been saved by a previous run of \duchamp. If
49  set true, the reconstructed array will be read from the file given
50  by \texttt{reconFile}, rather than calculated directly.
51\item[{reconFile [no default]}] The FITS file that contains the
52  reconstructed array. If \texttt{flagReconExists} is true and this
53  parameter is not defined, the default file that is looked for will
54  be determined by the \atrous parameters (see \S\ref{sec-recon}).
55\item[{flagSmoothExists [false]}] A flag to indicate whether the
56  Hanning-smoothed array has been saved by a previous run of \duchamp. If
57  set true, the smoothed array will be read from the file given
58  by \texttt{smoothFile}, rather than calculated directly.
59\item[{smoothFile [no default]}] The FITS file that has
60  a previously smoothed array. If \texttt{flagSmoothExists}
61  is true and this parameter is not defined, the default file that is
62  looked for will be determined by the smoothing parameters (see
63  \S\ref{sec-smoothing}).
64\item[{usePrevious [false]}] A flag to indicate that \duchamp should
65  read the list of objects from a previously-created log file, rather
66  than doing the searching itself. The set of outputs will be created
67  according to the flags in the following section.
68\item[{objectList [no default]}] When \texttt{usePrevious=true}, this
69  list is used to output individual spectral plots, as well as a
70  postscript file for all spectral plots as given by
71  \texttt{SpectraFile}. The filenames of the plots will be the same as
72  \texttt{SpectraFile}, but with -XX at the end, where XX is the
73  object number (\eg \texttt{duchamp-Spectra-07.ps}). The format of
74  the parameter value should be a string listing individual objects or
75  object ranges: \eg 1,2,4-7,8,14.
76\end{Lentry}
77
78\secB*{Output related}
79\begin{Lentry}
80\item[{OutFile [duchamp-\\Results.txt]}] The file containing the
81  final list of detections. This also records the list of input
82  parameters.
83\item[{flagSeparateHeader [false]}] A flag to indicate that the header
84  information that would normally be printed at the start of the
85  results file (containing information on the parameters, image
86  statistics and number of detections) should instead be written to a
87  separate file.
88\item[{HeaderFile [duchamp-\\Results.hdr]}] The file to which the
89  header information should be written when
90  \texttt{flagSeparateHeader=true}.
91\item[{SpectraFile [duchamp-\\Spectra.ps]}] The postscript file
92  containing the resulting integrated spectra and images of the
93  detections.
94\item[{flagTextSpectra [false]}] A flag to say whether the spectra
95  should be saved in text form in a single file. See below for a
96  description.
97\item[{spectraTextFile [duchamp-\\Spectra.txt]}] The file containing
98  the spectra of each object in ascii format. This file will have a
99  column showing the spectral coordinates, and one column for each of
100  the detected objects, showing the flux values as plotted in the
101  graphical output of \texttt{spectraFile}.
102\item[{flagLog [false]}] A flag to indicate whether the
103  details of intermediate detections should be logged.
104\item[{LogFile [duchamp-\\Logfile.txt]}] The file in which
105  intermediate detections are logged. These are detections that have
106  not been merged. This is primarily for use in debugging and
107  diagnostic purposes: normal use of the program will probably not
108  require it.
109\item[{flagOutputMomentMap [false]}] A flag to say whether or not to save a
110  FITS file containing the moment-0 map.
111\item[fileOutputMomentMap{ [see text]}] The file to which the moment-0 array is
112  written. If left blank (the default), the naming scheme detailed in
113  Section~\ref{sec-maskOut} is used.
114\item[{flagOutputMask [false]}] A flag to say whether or not to save a
115  FITS file containing a mask array, with values 1 where there is a
116  detected object and 0 elsewhere.
117\item[fileOutputMask{ [see text]}] The file to which the mask array is
118  written. If left blank (the default), the naming scheme detailed in
119  Section~\ref{sec-maskOut} is used.
120\item[{flagMaskWithObjectNum [false]}] If this flag is true, the
121  detected pixels in the mask image have the corresponding object ID
122  as their value. If false, they have the value 1. All non-detected
123  pixels have the value 0.
124\item[{flagOutputRecon [false]}] A flag to say whether or not
125  to save the reconstructed cube as a FITS file.
126\item[fileOutputRecon{ [see text]}] The file to which the reconstructed array
127  is written. If left blank (the default), the naming scheme detailed
128  in Section~\ref{sec-reconIO} is used.
129\item[{flagOutputResid [false]}] As for
130  \texttt{flagOutputRecon}, but for the residual array -- the
131  difference between the original cube and the reconstructed cube.
132\item[fileOutputResid{ [see text]}] The file to which the residual array
133  is written. If left blank (the default), the naming scheme detailed
134  in Section~\ref{sec-reconIO} is used.
135\item[{flagOutputSmooth [false]}] A flag to say whether or not
136  to save the smoothed cube as a FITS file.
137\item[fileOutputSmooth{ [see text]}] The file to which the smoothed array
138  is written. If left blank (the default), the naming scheme detailed
139  in Section~\ref{sec-reconIO} is used.
140\item[{flagVOT [false]}] A flag to say whether to create a
141  VOTable file with the detection information. This will be an XML
142  file in the Virtual Observatory VOTable format.
143\item[{votFile [duchamp-\\Results.xml]}] The VOTable file with
144  the list of final detections. Some input parameters are also
145  recorded.
146\item[{flagKarma [false]}] A flag to say whether to create a
147  Karma annotation file corresponding to the information in
148  \texttt{outfile}. This can be used as an overlay in Karma
149  programs such as \texttt{kvis}.
150\item[{karmaFile [duchamp-\\Results.ann]}] The Karma annotation
151  file showing the list of final detections.
152\item[{annotationType [borders]}] Which type of annotation plot to
153  use. Specifying ``borders'' gives an outline around the detected
154  spatial pixels, while ``circles'' gives a circle centred on the
155  centre of the object with radius large enough to encompass all
156  spatial pixels.
157\item[{flagMaps [true]}] A flag to say whether to save
158  postscript files showing the 0th moment map of the whole cube
159  (parameter \texttt{momentMap}) and the detection image
160  (\texttt{detectionMap}).
161\item[{momentMap [duchamp-\\MomentMap.ps]}] A postscript file
162  containing a map of the 0th moment of the detected sources, as well
163  as pixel and WCS coordinates.
164\item[{detectionMap [duchamp-\\DetectionMap.ps]}] A postscript
165  file with a map showing each of the detected objects, coloured in
166  greyscale by the number of detected channels in each spatial
167  pixel. Also shows pixel and WCS coordinates.
168\item[{flagXOutput [true]}] A flag to say whether to display a
169  0th moment map in a PGPlot X-window. This will be in addition to any
170  that are saved to a file. This parameter can be overridden by the
171  use of the \texttt{-x} command-line option, which disables the
172  X-windows output.
173\item[{newFluxUnits [no default]}] Flux units that the pixel values
174  should be converted into. These should be directly compatible with
175  the existing units, given by the BUNIT keyword.
176\item[{precFlux [3]}] The desired precision (\ie number of decimal
177  places) for flux values given in the output files and tables.
178\item[{precVel [3]}] The desired precision (\ie number of decimal
179  places) for velocity/frequency values given in the output files and
180  tables.
181\item[{precSNR [2]}] The desired precision (\ie number of decimal
182  places) for the peak SNR value given in the output files and tables.
183\end{Lentry}
184
185\secB*{Modifying the cube}
186\begin{Lentry}
187\item[{flagTrim [false]}] A flag to say whether to trim
188  BLANK pixels from the edges of the cube -- these are typically
189  pixels set to some particular value because they fall outside the
190  imaged area, and trimming them can help speed up the execution.
191\item[{flagMW [false]}] A flag to say whether to ignore
192  channels contaminated by Milky Way (or other) emission -- the
193  searching algorithms will not look at these channels.
194\item[{maxMW [112]}] The maximum channel number that contains
195  ``Milky Way'' emission. This is the channel number in the original
196  cube, before any subsection is applied.
197\item[{minMW [75]}] The minimum channel number that contains ``Milky
198  Way'' emission. This is the channel number in the original cube,
199  before any subsection is applied.  Note that the range specified by
200  \texttt{maxMW} and \texttt{minMW} is inclusive.
201\item[{flagBaseline [false]}] A flag to say whether to remove
202  the baseline from each spectrum in the cube for the purposes of
203  reconstruction and detection.
204\end{Lentry}
205
206\secB*{Detection related}
207
208\secC*{General detection}
209\begin{Lentry}
210\item[{flagStatSec [false]}] A flag indicating whether the
211  statistics should be calculated on a subsection of the cube, rather
212  than the full cube. Note that this only applies to the statistics
213  used to determine the threshold, and not for other statistical
214  calculations (such as those in the reconstruction phase).
215\item[{StatSec [ [*,*,*] ]}] The subsection of the cube used
216  for calculating statistics -- see \S\ref{sec-input} for details on
217 the subsection format. Only used if \texttt{flagStatSec=true}.
218\item[{flagRobustStats [true]}] A flag indicating whether to use the
219  robust statistics (median and MADFM) to estimate the noise
220  parameters, rather than the mean and rms. See \S\ref{sec-stats} for
221  details.
222\item[{flagNegative [false]}] A flag indicating that the
223  features of interest are negative. The cube is inverted prior to
224  searching.
225\item[{snrCut [3.]}] The threshold, in multiples of $\sigma$ above
226  the mean.
227\item[{threshold [no default]}] The actual value of the
228  threshold. Normally the threshold is calculated from the cube's
229  statistics, but the user can manually specify a value to be used
230  that overrides the calculated value. If this is not specified, the
231  calculated value is used, but this value will take precedence over
232  other means of calculating the threshold (\ie via \texttt{snrCut} or
233  the FDR method).
234\item[{flagGrowth [false]}] A flag indicating whether or not to
235  grow the detected objects to a smaller threshold.
236\item[{growthCut [3.]}] The smaller threshold using in growing
237  detections. In units of $\sigma$ above the mean.
238\item[{growthThreshold [no default]}] Alternatively, the threshold to
239  which detections are grown can be specified in flux units (in the
240  same manner as the \texttt{threshold} parameter). When the
241  \texttt{threshold} parameter is given, this option \textbf{must} be
242  used instead of \texttt{growthCut}.
243\item[{beamFWHM [-1.]}] The full-width at half maximum of the beam, in
244  pixels.  If the header keywords BMAJ and BMIN are present, then
245  these will be used to calculate the beam area, and this parameter
246  will be ignored. This will take precedence over \texttt{beamArea}
247  (but is ignored if not specified).
248\item[{beamArea [10.]}] The \textbf{area} of the beam in pixels (\ie
249  how many pixel does the beam cover?). As above, if the header
250  keywords BMAJ and BMIN are present, then these will be used to
251  calculate the beam area, and this parameter will be ignored.
252\end{Lentry}
253
254\secC*{\Atrous reconstruction}
255\begin{Lentry}
256\item[{flagATrous [false]}] A flag indicating whether or not to
257  reconstruct the cube using the \atrous wavelet
258  reconstruction. See \S\ref{sec-recon} for details.
259\item[{reconDim [1]}] The number of dimensions to use in the
260  reconstruction. 1 means reconstruct each spectrum separately, 2
261  means each channel map is done separately, and 3 means do the whole
262  cube in one go.
263\item[{scaleMin [1]}] The minimum wavelet scale to be used in the
264  reconstruction. A value of 1 means ``use all scales''.
265\item[{scaleMax [0]}] The maximum wavelet scale to be used in the
266  reconstruction. If the value is $\le0$ then the maximum scale is
267  calculated from the size of the input array. Similarly, if the value
268  given is larger than this calculated value, the calculated value is
269  used instead.
270\item[{snrRecon [4]}] The thresholding cutoff used in the
271  reconstruction -- only wavelet coefficients this many $\sigma$ above
272  the mean (or greater) are included in the reconstruction.
273\item[{filterCode [1]}] The code number of the filter to use in
274  the reconstruction. The options are:
275  \begin{itemize}
276  \item \textbf{1:} B$_3$-spline filter: coefficients =
277    $(\frac{1}{16}, \frac{1}{4}, \frac{3}{8}, \frac{1}{4}, \frac{1}{16})$
278  \item \textbf{2:} Triangle filter: coefficients =
279    $(\frac{1}{4}, \frac{1}{2}, \frac{1}{4})$
280  \item \textbf{3:} Haar wavelet: coefficients =
281    $(0, \frac{1}{2}, \frac{1}{2})$
282  \end{itemize}
283\end{Lentry}
284
285\secC*{Smoothing the cube}
286\begin{Lentry}
287\item[{flagSmooth [false]}] A flag indicating whether to
288  smooth the cube. See \S\ref{sec-smoothing} for details.
289\item[{smoothType [spectral]}] The smoothing method used: either
290  ``spectral'' (with a 1D Hanning filter) or ``spatial'' (with a 2D
291  Gaussian filter). 
292\item[{hanningWidth [5]}] The width of the Hanning smoothing
293  kernel.
294\item[{kernMaj [3]}] The full-width-half-maximum (FWHM) of the
295  2D Gaussian smoothing kernel's major axis.
296\item[{kernMin [3]}] The FWHM of the 2D Gaussian smoothing kernel's
297  minor axis.
298\item[{kernPA [0]}] The position angle, in degrees,
299  anticlockwise from vertical (\ie usually East of North).
300\end{Lentry}
301
302\secC*{FDR method}
303\begin{Lentry}
304\item[{flagFDR [false]}] A flag indicating whether or not to use
305  the False Discovery Rate method in thresholding the pixels.
306\item[{alphaFDR [0.01]}] The $\alpha$ parameter used in the FDR
307  analysis. The average number of false detections, as a fraction of
308  the total number, will be less than $\alpha$ (see
309  \S\ref{sec-detection}).
310\item[{FDRnumCorChan [2]}] The number of neighbouring spectral
311  channels that are assumed to be correlated. This is needed by the
312  FDR algorithm to calculate the normalisation constant $c_N$ (see
313  \S\ref{sec-detection}).
314\end{Lentry}
315
316\secC*{Merging detections}
317\begin{Lentry}
318\item[{minPix [2]}] The minimum number of spatial pixels for a
319  single detection to be counted.
320\item[{minChannels [3]}] At least one contiguous set of this many
321  channels must be present in the detection for it to be accepted.
322\item[{flagRejectBeforeMerge [false]}] A flag indicating whether to
323  reject sources that fail to meet the \texttt{minPix} or
324  \texttt{minChannels} criteria \textbf{before} the merging
325  stage. Default behaviour is to do the rejection last.
326\item[{flagAdjacent [true]}] A flag indicating whether to use
327  the ``adjacent pixel'' criterion to decide whether to merge
328  objects. If not, the next two parameters are used to determine
329  whether objects are within the necessary thresholds.
330\item[{threshSpatial [3.]}] The maximum allowed minimum spatial
331  separation (in pixels) between two detections for them to be merged
332  into one. Only used if \texttt{flagAdjacent = false}.
333\item[{threshVelocity [7.]}] The maximum allowed minimum channel
334  separation between two detections for them to be merged into
335  one.
336\end{Lentry}
337
338\secC*{Other parameters}
339\begin{Lentry}
340\item[{spectralMethod [peak]}] This indicates which method is used
341  to plot the output spectra: \texttt{peak} means plot the spectrum
342  containing the detection's peak pixel; \texttt{sum} means sum the
343  spectra of each detected spatial pixel, and correct for the beam
344  size. Any other choice defaults to \texttt{peak}.
345\item[{spectralUnits [km/s]}] The user can specify the units of
346  the spectral axis. Assuming the WCS of the FITS file is valid, the
347  spectral axis is transformed into velocity, and put into these units
348  for all output and for calculations such as the integrated flux of a
349  detection.
350\item[{pixelCentre [centroid]}] Which of the three ways of
351  expressing the ``centre'' of a detection (see \S\ref{sec-results}
352  for a description of the options) to use for the X, Y, \& Z
353  columns in the output list. Alternatives are: \texttt{centroid, peak,
354  average}.
355\item[{sortingParam [vel]}] The parameter on which to sort the output
356  list of detected objects. Options are: x-value, y-value, z-value,
357  ra, dec, vel, w50, iflux,  pflux (integrated and peak flux
358  respectively), or snr.
359\item[{drawBorders [true]}] A flag indicating whether to draw
360  borders around the detected objects in the moment maps included in
361  the output (see for example Fig.~\ref{fig-spect}).
362\item[{drawBlankEdges [true]}] A flag indicating whether to
363  draw the dividing line between BLANK and non-BLANK pixels on the
364  2D images (see for example Fig.~\ref{fig-moment}).
365\item[{verbose [true]}] A flag indicating whether to print the
366  progress of any computationally intensive algorithms (\eg
367  reconstruction, searching or merging algorithms) to the screen.
368\end{Lentry}
369
Note: See TracBrowser for help on using the repository browser.