from scantable import scantable from asap import rcParams def average_time(*args, **kwargs): """ Return the (time) average of a scan or list of scans. [in channels only] Parameters: one scan or comma separated scans mask: an optional mask (only used for 'var' and 'tsys' weighting) scanav: False (default) averages all scans together, True averages each scan separately weight: Weighting scheme. 'none' (default), 'var' (variance weighted), 'tsys' Example: # return a time averaged scan from scana and scanb # without using a mask scanav = average_time(scana,scanb) # return the (time) averaged scan, i.e. the average of # all correlator cycles scanav = average_time(scan) """ scanAv = False if kwargs.has_key('scanav'): scanAv = kwargs.get('scanav') weight = 'none' if kwargs.has_key('weight'): weight = kwargs.get('weight') mask = () if kwargs.has_key('mask'): mask = kwargs.get('mask') lst = tuple(args) from asap._asap import average as _av for s in lst: if not isinstance(s,scantable): print "Please give a list of scantables" return return scantable(_av(lst, mask, scanAv, weight)) def quotient(source, reference, preserve=True): """ Return the quotient of a 'source' (signal) scan and a 'reference' scan. The reference can have just one row, even if the signal has many. Otherwise they must have the same number of rows. Parameters: source: the 'on' scan reference: the 'off' scan preserve: you can preserve (default) the continuum or remove it. The equations used are preserve - Output = Tref * (sig/ref) - Tref remove - Output = Tref * (sig/ref) - Tsig """ from asap._asap import quotient as _quot return scantable(_quot(source, reference, preserve)) def simple_math(left, right, op='add'): """ Apply simple mathematical binary operations to two scan tables, returning the result in a new scan table. The operation is applied to both the correlations and the TSys data Parameters: left: the 'left' scan right: the 'right' scan op: the operation: 'add' (default), 'sub', 'mul', 'div' """ if not isinstance(left,scantable) and not isinstance(right,scantable): print "Please provide two scantables as input" return from asap._asap import b_operate as _bop return scantable(_bop(left, right, op)) def scale(scan, factor, insitu=None, allaxes=None): """ Return a scan where all spectra are scaled by the give 'factor' Parameters: scan: a scantable factor: the scaling factor insitu: if False a new scantable is returned. Otherwise, the scaling is done in-situ The default is taken from .asaprc (False) allaxes: if True apply to all spectra. Otherwise apply only to the selected (beam/pol/if)spectra only. The default is taken from .asaprc (True) """ if allaxes is None: allaxes = rcParams['scantable.allaxes'] if insitu is None: insitu = rcParams['insitu'] if not insitu: from asap._asap import scale as _scale return scantable(_scale(scan, factor, allaxes)) else: from asap._asap import scale_insitu as _scale _scale(scan, factor, allaxes) return def add(scan, offset, insitu=None, allaxes=None): """ Return a scan where all spectra have the offset added Parameters: scan: a scantable offset: the offset insitu: if False a new scantable is returned. Otherwise, the scaling is done in-situ The default is taken from .asaprc (False) allaxes: if True apply to all spectra. Otherwise apply only to the selected (beam/pol/if)spectra only The default is taken from .asaprc (True) """ if allaxes is None: allaxes = rcParams['scantable.allaxes'] if insitu is None: insitu = rcParams['insitu'] if not insitu: from asap._asap import add as _add return scantable(_add(scan, offset, allaxes)) else: from asap._asap import add_insitu as _add _add(scan, offset, allaxes) return def convert_flux(scan, area, eta=1.0, insitu=None, allaxes=None): """ Return a scan where all spectra are converted to either Jansky or Kelvin depending upon the flux units of the scan table. Parameters: scan: a scantable area: the illuminated area of the telescope (m**2) eta: The efficiency of the telescope (default 1.0) insitu: if False a new scantable is returned. Otherwise, the scaling is done in-situ The default is taken from .asaprc (False) allaxes: if True apply to all spectra. Otherwise apply only to the selected (beam/pol/if)spectra only The default is taken from .asaprc (True) """ if allaxes is None: allaxes = rcParams['scantable.allaxes'] if insitu is None: insitu = rcParams['insitu'] if not insitu: from asap._asap import convertflux as _convert return scantable(_convert(scan, area, eta, allaxes)) else: from asap._asap import convertflux_insitu as _convert _convert(scan, area, eta, allaxes) return def gain_el(scan, poly=None, filename="", method="linear", insitu=None, allaxes=None): """ Return a scan after applying a gain-elevation correction. The correction can be made via either a polynomial or a table-based interpolation (and extrapolation if necessary). You specify polynomial coefficients, an ascii table or neither. If you specify neither, then a polynomial correction will be made with built in coefficients known for certain telescopes (an error will occur if the instrument is not known). Parameters: scan: a scantable poly: Polynomial coefficients (default None) to compute a gain-elevation correction as a function of elevation (in degrees). filename: The name of an ascii file holding correction factors. The first row of the ascii file must give the column names and these MUST include columns "ELEVATION" (degrees) and "FACTOR" (multiply data by this) somewhere. The second row must give the data type of the column. Use 'R' for Real and 'I' for Integer. An example file would be: TIME ELEVATION FACTOR R R R 0.1 0 1.5 0.2 20 1.4 0.3 40 1.3 0.4 60 1.2 0.5 80 1.1 0.6 90 1.0 method: Interpolation method when correcting from a table. Values are "nearest", "linear" (default), "cubic" and "spline" insitu: if False a new scantable is returned. Otherwise, the scaling is done in-situ The default is taken from .asaprc (False) allaxes: if True apply to all spectra. Otherwise apply only to the selected (beam/pol/if) spectra only The default is taken from .asaprc (True) """ if allaxes is None: allaxes = rcParams['scantable.allaxes'] if poly is None: poly = () if insitu is None: insitu = rcParams['insitu'] if not insitu: from asap._asap import gainel as _gainEl return scantable(_gainEl(scan, poly, filename, method, allaxes)) else: from asap._asap import gainel_insitu as _gainEl _gainEl(scan, poly, filename, method, allaxes) return def align(scan, insitu=None): """ Return a scan where all rows have been aligned in velocity. The velocity reference frame (e.gh. LSRK), unit and doppler (e.g. OPTICAL) are those set by functions set_unit and set_freqframe. The data are aligned to the velocity abcissa at the first time present in the data. scan: a scantable insitu: if False a new scantable is returned. Otherwise, the scaling is done in-situ The default is taken from .asaprc (False) """ if insitu is None: insitu = rcParams['insitu'] if not insitu: from asap._asap import align as _align return scantable(_align(scan)) else: from asap._asap import align_insitu as _align _align(scan) return def opacity(scan, tau, insitu=None, allaxes=None): """ Return a scan after applying an opacity correction. Parameters: scan: a scantable tau: Opacity from which the correction factor is exp(tau*ZD) where ZD is the zenith-distance insitu: if False a new scantable is returned. Otherwise, the scaling is done in-situ The default is taken from .asaprc (False) allaxes: if True apply to all spectra. Otherwise apply only to the selected (beam/pol/if)spectra only The default is taken from .asaprc (True) """ if allaxes is None: allaxes = rcParams['scantable.allaxes'] if insitu is None: insitu = rcParams['insitu'] if not insitu: from asap._asap import opacity as _opacity return scantable(_opacity(scan, tau, allaxes)) else: from asap._asap import opacity_insitu as _opacity _opacity(scan, tau, allaxes) return def bin(scan, width=5, insitu=None): """ Return a scan where all spectra have been binned up width: The bin width (default=5) in pixels insitu: if False a new scantable is returned. Otherwise, the scaling is done in-situ The default is taken from .asaprc (False) """ if insitu is None: insitu = rcParams['insitu'] if not insitu: from asap._asap import bin as _bin return scantable(_bin(scan, width)) else: from asap._asap import bin_insitu as _bin _bin(scan, width) return def average_pol(scan, mask=None, insitu=None): """ Average the Polarisations together. Parameters: scan: The scantable mask: An optional mask defining the region, where the averaging will be applied. The output will have all specified points masked. insitu: if False a new scantable is returned. Otherwise, the scaling is done in-situ The default is taken from .asaprc (False) Example: polav = average_pols(myscan) """ if mask is None: mask = () if insitu is None: insitu = rcParams['insitu'] if not insitu: from asap._asap import averagepol as _avpol return scantable(_avpol(scan, mask)) else: from asap._asap import averagepol_insitu as _avpol _avpol(scan, mask) return def smooth(scan, kernel="hanning", width=5.0, insitu=None, allaxes=None): """ Smooth the spectrum by the specified kernel (conserving flux). Parameters: scan: The input scan kernel: The type of smoothing kernel. Select from 'hanning' (default), 'gaussian' and 'boxcar'. The first three characters are sufficient. width: The width of the kernel in pixels. For hanning this is ignored otherwise it defauls to 5 pixels. For 'gaussian' it is the Full Width Half Maximum. For 'boxcar' it is the full width. insitu: if False a new scantable is returned. Otherwise, the scaling is done in-situ The default is taken from .asaprc (False) allaxes: If True (default) apply to all spectra. Otherwise apply only to the selected (beam/pol/if)spectra only The default is taken from .asaprc (True) Example: none """ if allaxes is None: allaxes = rcParams['scantable.allaxes'] if insitu is None: insitu = rcParams['insitu'] if not insitu: from asap._asap import smooth as _smooth return scantable(_smooth(scan,kernel,width,allaxes)) else: from asap._asap import smooth_insitu as _smooth _smooth(scan,kernel,width,allaxes) return def poly_baseline(scan, mask=None, order=0, insitu=None): """ Return a scan which has been baselined (all rows) by a polynomial. Parameters: scan: a scantable mask: an optional mask order: the order of the polynomial (default is 0) insitu: if False a new scantable is returned. Otherwise, the scaling is done in-situ The default is taken from .asaprc (False) Example: # return a scan baselined by a third order polynomial, # not using a mask bscan = poly_baseline(scan, order=3) """ from asap.asapfitter import fitter if mask is None: from numarray import ones mask = tuple(ones(scan.nchan())) f = fitter() f._verbose(True) f.set_scan(scan, mask) f.set_function(poly=order) sf = f.auto_fit(insitu) return sf