Opened 7 years ago
Last modified 7 years ago
#525 closed defect
Spectral plotting broken — at Initial Version
Reported by: | MatthewWhiting | Owned by: | MatthewWhiting |
---|---|---|---|
Priority: | normal | Milestone: | Release-1.6.2 |
Component: | Output | Version: | 1.6.1 |
Severity: | normal | Keywords: | |
Cc: |
Description
As reported by Anne Klitsch, there is a WCS error coming up in the spectral plotting.
This is actually happening in the verification scripts as well, and so definitely needs to be fixed!
Original report: {{ My name is Anne Klitsch and I am a PhD student at ESO in Germany. I am interested in galaxies connected to known Lyman alpha absorbers. We have a number of observations from ALMA targeting CO emission lines in fields with known intervening absorbers and I want to use Duchamp as a source finder. I have tried to install it on my mac book and it runs in principle smoothly. However, if I run Duchamp on one of my cubes or even if I run the verification script I get the following error: ERROR <pixToWCSSingle> : WCS Error Code = 8: stat=3 : One or more of the pixel coordinates were invalid }}